SW_LP_x_CA_1B

LP calibration parameters

Thematic areas: Plasma measurements

Applicable missions: Swarm

Applicable spacecraft: Swarm-A, Swarm-B, Swarm-C

Description

The LP_X_CA_1B Product contains the TCF.LP Data Set records, that is a the Temporal Calibration File containing the LP calibration parameters determined in the L1B Processor from the Offset Determination Sweep Mode telemetry including the measurements themselves.

Data access

FAST processing

N/A

Preview image

(delivered separately)

File contents

Variable Units Description Dim Type
Timestamp UTC Time stamp 1 CDF_EPOCH
SyncStatus - Synchronization status 1 CDF_UINT2
Probe1_I_Bias_Offset V Probe 1 current bias offset 1 CDF_DOUBLE
Probe1_I_Slope_Offset V Probe 1 current slope offset 1 CDF_DOUBLE
Probe1_I_Fit_Error V Probe 1 current fit error 1 CDF_DOUBLE
Probe1_U_Bias_Offset V Probe 1 voltage bias offset 1 CDF_DOUBLE
Probe1_U_Slope_Offset V Probe 1 voltage slope offset 1 CDF_DOUBLE
Probe1_U_Fit_Error V Probe 1 voltage sweep fit error 1 CDF_DOUBLE
Probe2_I_Bias_Offset V Probe 2 current bias offset 1 CDF_DOUBLE
Probe2_I_Slope_Offset V Probe 2 current slope offset 1 CDF_DOUBLE
Probe2_I_Fit_Error V Probe 2 current fit error 1 CDF_DOUBLE
Probe2_U_Bias_Offset V Probe 2 voltage bias offset 1 CDF_DOUBLE
Probe2_U_Slope_Offset V Probe 2 voltage slope offset 1 CDF_DOUBLE
Probe2_U_Fit_Error V Probe 2 voltage sweep fit error 1 CDF_DOUBLE
FP_I_Bias_Offset V Face Plate current bias offset 1 CDF_DOUBLE
FP_I_Slope_Offset V Face Plate current slope offset 1 CDF_DOUBLE
FP_I_Fit_Error V Face Plate current sweep fit error 1 CDF_DOUBLE
FP_U_Bias_Offset V Face Plate voltage bias offset 1 CDF_DOUBLE
FP_U_Slope_Offset V Face Plate voltage slope offset 1 CDF_DOUBLE
FP_U_Fit_Error V Face Plate voltage sweep fit error 1 CDF_DOUBLE
FP_I_offset eu Face Plate current offset measurements 32 CDF_INT2
FP_U_offset eu Face Plate bias offset measurements 32 CDF_INT2
P1_I_offset eu Probe 1 current offset measurements 32 CDF_INT2
P1_U_offset eu Probe 1 bias offset measurements 32 CDF_INT2
P1_ref_ADC2 eu Probe 1 reference ADC2 32 CDF_INT2
P1_ground eu Probe 1 ground 32 CDF_INT2
P2_I_offset eu Probe 2 current offset measurements 32 CDF_INT2
P2_U_offset eu Probe 2 bias offset measurements 32 CDF_INT2
P2_ref_ADC2 eu Probe 2 reference ADC2 32 CDF_INT2
P2_ground eu Probe 2 ground 32 CDF_INT2
P1_Slope V robe 1 slope offset, determined on-board 1 CDF_DOUBLE
P1_Bias V Probe 1 bias offset, determined on-board 1 CDF_DOUBLE
P1_Error V Probe 1 sweep fit error, determined on-board 1 CDF_DOUBLE
P2_Slope V Probe 2 slope offset, determined on-board 1 CDF_DOUBLE
P2_Bias V Probe 2 bias offset, determined on-board 1 CDF_DOUBLE
P2_Error V Probe 2 sweep fit error, determined on-board 1 CDF_DOUBLE

More details

N/A

Related resources

Level 1B Product Descriptions:

Level 1B Product Format page:

Changelog

N/A