SW_EFIxTIE_2_

Estimated ion temperatures along the Swarm satellite orbits

Thematic areas: Plasma measurements, Space Weather

Applicable missions: Swarm

Applicable spacecraft: Swarm-A, Swarm-B, Swarm-C

Description

This product contains estimated ion temperatures along the Swarm satellite orbits

Data access

FAST processing

N/A

Preview image

(delivered separately)

File contents

Variable Units Description Dim Type
Timestamp ms Milliseconds since Jan 1, UTC 1 CDF_EPOCH
Latitude degrees Geodetic latitude 1 CDF_REAL8
Longitude degrees Geodetic longitude 1 CDF_REAL8
Radius m Geocentric radius 1 CDF_REAL8
Height m Height above WGS84 reference ellipsoid 1 CDF_REAL8
QDLatitude degrees Quasi-dipole magnetic latitude 1 CDF_REAL8
MLT hour Magnetic local time 1 CDF_REAL8
Ti_meas_drift K Ion temperature estimated using Swarm TII drift at high latitudes 1 CDF_REAL8
Ti_model_drift K Ion temperature estimated using Weimer 2005 model drifts at high latitudes 1 CDF_REAL8
Te_adj_LP K Corrected Swarm LP electron temperature 1 CDF_REAL8
Tn_msis K Neutral temperature from NRLMSISE-00 model 1 CDF_REAL8
Flag_ti_meas Bitwise flag for ‘Ti_meas_drift’ identifying included inputs and processes, see section 3.5 in Swarm SITE product description document 1 CDF_UINT1
Flag_ti_model Bitwise flag for ‘Ti_model_drift’ identifying included inputs and processes, see section 3.5 in Swarm SITE product description document 1 CDF_UINT1

More details

Product identifier EFIxTIE_2_
Definition Estimated ion temperatures along the Swarm satellite orbits
Input data SW_EXTD_EFIX_LP, SW_EXPT_EFIX_TCT02, empirical models: NRLMSISE-00, HWM14, Weimer 2005
Input time span 1 day
Spatial representation Estimates along the Swarm satellite’s orbit
Time representation Time series in every 0.5 seconds
Units Kelvin
Resolution 1 K
Uncertainty ~ 20 %
Data volume ~8 MB (daily file)
Data format CDF
Output time span 1 day
Update rate two months
Latency 6 minutes
Notes  
Flag bit number
Variable CDF Type Unit
0 0/1 High-latitude frictional heating omitted/included
1 0/1 Used is high-gain/low-gain LP Te
2 0/1 Estimated ion temperature not available(= −9999)/available

Related resources

Changelog

N/A